DESCRIPTION

Use code CCFTWZV2NJG3  for an instant 15% discount on checkout!

 The Model 150 uses the latest in microprocessor capability, giving the user a high level of application flexibility. Multiple inputs and very easy setup characterize this new technology.

This controller can be used in the Continuous Sample, Sample/Cycle, or Sample/Hold modes to control the boiler water conductivity.

From the drop down, please add sensor, orifice and union, and the motorized ball valve

OPTIONS
     FEATURES

     Use this Controller for conductivity control of boilers. It can be used for Continuous Sample, Sample/Cycle, or Sample/Hold control of boiler conductivity.

    • Removable power cord and receptacles for simple conduit installations.

    • One (1) water meter input, conductivity input, flow switch input, and 4-20 mA output are all standard features.

    • Designed with a single circuit board for better reliability and lower cost.

    • Large open shallow enclosure for easy wiring.

    • The enclosure is rated NEMA 4X.

    • Power selector switch for 115 or 230 vac operation.

    • Heavy-duty stainless steel domed numeric keypad and illuminated graphical display allow for quick and easy programming. Steel domed switches improve the tactile sensing and life expectancy of the keypad.

    • LED indicators for power, alarm and relay status.

    • The display is lit by two LEDs when any key is pressed.

    BENEFITS

     Easy to program, the Model 150 Controller uses an intuitive menu and a numeric keypad for programming.

    • No add-on options. Flow switch input, 4-20mA output, and three boiler conductivity control methods; Continuous Sample, Sample/Cycle, and Sample/Hold are standard.

    • Single circuit board design improves reliability.

      Multiple methods of chemical feed for application flexibility.

    SPECIFICATIONS
     Conductivity range 100-10,000 μS
    Conductivity sensor 2 electrode
    Conductivity Resolution ± 10 μS
    Accuracy & repeatability ± 1.0%
    Deadband/Setpoint Adjustable
    Auto/Manual outputs Menu selectable
    Output relays 2 selectable use and 1 for blowdown
    Keypad 16 tactile push-buttons
    Display 16 X 2 Character
    Water meter input Contact head, paddle wheel or turbine
    Timer Max. blowdown time exceeded, relay time exceeded
    Output Signal One 4 – 20 mA, non-isolated powered output
    Relay ratings 3A each, 10A total
    Power 120/240 VAC 50/60 Hz
    Ambient 32° - 120°F (0 - 49°C)